5.8 Encoder
Feedback
5.8.1 Encoder card
verification
Parameters LF.26...LF.2 and optionally parameters LF.76 and LF.77 are
used to establish the encoder feedback.
The most important point is to verify that the installed feedback card matches
the encoder type on the motor. The drive supports many different types
of encoders, some of which require different feedback cards as options.
Parameter 0.LF.26 displays the type of encoder feedback card which is
currently installed. From the list below verify the encoder interface on the
drive matches the encoder on the motor.
0.LF.26
Type of encoder card installed in the drive
rESoL
Resolver
HIPEr
Hiperface
Inc24
15-24V HTL incremental
IncIE
5V TTL incremental
SinCo
Sine Cosine
I24PE
15-24V HTL incremental
EndAt
EnDat Encoder
PHASE
UVW Encoder
Initial Start Up