Analog Pre-Torque Raw; Analog Pre-Torque Processed; Analog Option Raw; Analog Option Processed - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Diagnostic parameters
ru.29
This parameter displays the value of the actual pre-torque signal applied between
terminal X2A.3 and X2A.4. The value is in percent +/- 100.0% = +/- 10.00V. This
Analog pre-
value is unfiltered and unprocessed.
torque raw
Units: %
ru.30
This parameter displays the processed analog pre-torque value. Filters, offsets and
gains are applied to this value. Again 100.0% = 10.00V on the input.
Analog
pre-torque
Units: %
processed
This parameter displays the value of the analog signal applied to an option interface
ru.31
board. The value is in percent +/- 100.0% = +/- 10.00V. This value is unfiltered
Analog option
and unprocessed.
raw
Units: %
ru.32
This parameter displays the processed analog option value. Filters, offsets and
gains are applied to this value. Again 100.0% = 10.00V on the input.
Analog option
processed
Units: %
ru.33
Analog output 1 preamp display. The value is in percent +/- 100.0% = +/- 10.00V.
Analog Out 1
Units:%
preamp
ru.34
Analog output 1 post amp display. The value is in percent +/- 100.0% = +/-
10.00V.
Analog Out 1
post-amp
Units:%
ru.35
Analog output 2 preamp display. The value is in percent +/- 100.0% = +/- 10.00V.
Analog Out 2
Units:%
preamp
ru.36
Analog output 2 post amp display. The value is in percent +/- 100.0% = +/-
10.00V.
Analog Out 2
post-amp
Units:%
ru.37
Value of the internal function.
Units:%
Motor pot value
128

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents