Switching conditions for the digital outputs. Only one condition can be assigned to each
output.
Designator Function
FLt
Fault - indicates there is a drive fault. Output activates when there is a drive
fault, E.xxx
Rdy
Ready - indicates the drive is ready for operation. Output activates when the
drive and ready for operation and there are no active faults E.xxx
dro
Drive On - indicates the drive is on and in control of the motor. Output activates
after the following conditions are met: enable input active, direction input active,
motor phase current check passed, motor magnetizing current OK. The output
turns off when one of the following occurs: enable input is turned off, direction
input is turned off and the motor speed has decelerated to zero speed and timer
LF.78 has expired, drive fault E.xx, current to the motor is interrupted for any
other reason.
ASd
At Speed - indicates the actual speed is tracking the command speed. Output
is active as long as the actual speed matches the commanded speed. If during
operation the actual speed is greater than or less than the commanded value, the
output will turn off. See also parameters LF.57, LF.58, LF.5 for adjustment.
HSd
High Speed Run - indicates when the actual motor speed is above twice the
value adjusted in LF. 41 (leveling speed). The output turns on when the actual
speed is greater than 2 x LF.41. When the actual speed drops below 1.5 times
LF.41 the output turns off. The speed is measured by the motor encoder.
brC
Brake Control - for controlling the brake. Output activates after the following con-
ditions are met: enable input active, direction input active, motor phase current
check passed, motor magnetizing current OK. The output turns off when one of
the following occurs: enable input is turned off, direction input is turned off, drive
fault E.xx, current to the motor is interrupted for any other reason.
Mcc
Main Contactor Control - for controlling the main motor contactor. Output acti-
vates after the following condition is met: enable input active. The output turns
off when one of the following occurs: enable input is turned off, drive fault E.xx.
Note: when using this input, it is necessary to qualify the direction signal(s)
through an auxiliary contact on the main contact for proper timing.