Advanced Drive Data
Ld.25
Vmax regulation
Ld.27
KP current
Ld.28
KI current
Ld.30
System inertia
Ld.31
FFTC filter
Ld.32
FFTC gain
Ld.33
Torque \command filter
150
Sets the output voltage level the drive will regulate. The drive will
prevent the output voltage from going above this value by reducing
the magnetizing current. 50...110%
Current control proportional gain. Same as LF.34.
Current control integral gain. Same as LF.35.
The total inertial, motor and load in kgcm
Feed forward torque control filter. Provides a filter on the output
of the FFTC.
0=off, 1=2msec, 2=4mSec, 3=8mSec, 4=16mSec, etc.
Determines the relative gain of the feed forward torque command.
100% = unity command
Provides a PT1 filter on the torque command signal before it is
feed into the current control.
0=off, 1=0.5msec, 2=1msec, 3=2msec, 4=4mSec, 5=8mSec, etc
.