OPERATING CONDITIONS

3 Technical Data

Unless otherwise indicated, all electrical data in the following chapter refer to a 3-phase
AC mains.
3.1 Operating conditions

3.1.1 Climatic environmental conditions

Storage
Ambient temperature
Relative humidity
Storage height
Transport
Ambient temperature
Relative humidity
Operation
Ambient temperature
Coolant inlet tem-
Air
perature
Relative humidity
Version and degree of protection
Site altitude
Table 2:
Climatic environmental conditions
Standard
Class
1K4
EN 60721-3-1
EN 60721-3-1
1K3
Standard
Class
EN 60721-3-2
2K3
2K3
EN 60721-3-2
Standard
Class
EN 60721-3-3
3K3
EN 60721-3-3
3K3
IP20
EN 60529
Descriptions
-25...55 °C
5...95 % (without condensation)
Max. 3000 m above sea level
Descriptions
-25...70 °C
95 % at 40 °C (without condensation)
Descriptions
5...40 °C (extended to -10...45 °C)
5...40 °C (extended to -10...45 °C)
5...85 % (without condensation)
Protection
against
foreign
ø12.5 mm
No protection against water
Non-conductive pollution, occasional con-
densation when PDS is out of service.
Drive controller generally, except power con-
nections and fan unit (IPxxA)
Max. 2000 m above sea level
With site altitudes over 1000 m a derat-
ing of 1 % per 100 m must be taken into
consideration.
With site altitudes over 2000 m, the con-
trol board to the mains has only basic
isolation. Additional measures must be
taken when wiring the control.