KEB COMBIVERT F5 Instruction Manual page 19

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

1) The wire gauge is based on the maximum fuse rating, copper wire with a 75°C insulation rating, THHW or equivalent. If circuit protection is selected
based on the actual input current, the wire size could be reduced.
2) This is the peak output current limited by hardware regulation. The software current control reserves 5% for closed loop regulation.
3) This is the maximum carrier frequency the power stage can support. The actual operating carrier frequency is adjusted and limited by the control
card.
4) This is the power dissipation at the rated carrier frequency, rated voltage and rated load. Operation at reduced carrier frequencies or reduced load
will decrease this value.
5) Max motor cable length when using shielded cable, KEB EMI filter, and the installation must conform to EN55011 / EN55022.
Technical Data
Inverter Size
Recommended Motor Power
Housing size
Input Ratings
Supply voltage [V]
Supply voltage frequency [Hz]
Input phases
Rated input current [A]
Recommended wire gauge
Output Ratings
Rated output power [kVA]
Rated motor power [kW]
Rated output current [A]
Peak current (30 seconds)
Over current fault (E.OC) trip level [A]
Output voltage [V]
Output frequency [Hz]
Rated switching frequency [kHz]
Maximum switching frequency
Power loss at rated operation
Stall current at 4kHz [A]
Stall current at 8kHz [A]
Stall current at 16kHz [A]
Braking Circuit
Min. braking resistance [Ohm]
Typ. braking resistance [Ohm]
Max. braking current [A]
Installation Information
Max. shielded motor cable length
Tightening torque for power terminals [in lb]
Environmental
Max. heat sink temperature TOH [°C]
Storage temperature [°C]
Operating temperature [°C]
Housing design / protection
Relative humidity
Approvals
Tested in accordance with...
Standards for emitted interference
Standards for noise immunity
Climatic category
18
19
20
[hp]
30
40
50
R
R
R
180...260 ±0 (230 V rated voltage)
50 / 60 +/- 2
3
3
3
88
115
143
1)
[awg]
3
1
2/O
35
42
52
22
30
37
80
104
130
2)
[A]
150
172
217
162
207
270
3 x 0...V input (3 x 0...255V
Generally 0 to 1600Hz (limited by carrier frequency)
8
8
8
3)
[kHz]
16
16
16
4)
[W]
1020
1200
1400
110
123
160
100
115
145
70
70
101
4.7
3.
2.0
5.6
4.7
3.
85
102
160
5)
[ft]
165
53
0°C / 14°F
-25...70 °C / -13...158°F
-10...45 °C / 14...113°F
Chassis / IP20 / Pollution Degree 2
max. 5% without condensation
EN 61800-3 /UL508C
EN 55011 Class B / EN 55022 Class A
IEC 1000-4-2 / -3 / -4 / -5/ -6
3K3 in accordance with EN 50178
21
60
R
3
170
3/O
62
45
154
270
315
2)
)
8
16
1700
18
180
101
2.0
3.0
160
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents