Diagnostic parameters
7.0 Run Parameters
ru. 0
This parameter displays the operational status of the inverter. The status codes are
defined with parameter LF..
Inverter state
ru. 1
This parameter displays the set speed or commanded value. This value is before
the ramp generator.
Set speed
Units: rpm
ru. 2
This parameter displays the actual commanded speed of the motor. This is the
speed the motor should turn at.
Command
speed
Units: rpm
ru. 3
This is the actual output frequency to the motor.
Actual output
Units: Hz
frequency
ru. 7
This is the processed actual speed value as measured by the motor encoder.
Actual speed
Units: rpm
value
ru. 9
This is the raw measured speed value as measured by the encoder connected to
input X3A.
Encoder 1
speed
Units: rpm
This is the raw measured speed value as measured by the encoder connected to
ru.10
input X3B.
Encoder 2
speed
Units: rpm
124
The run parameters display operational values within the elevator
drive. They can be used for trouble shooting or calibration purposes.
Each parameter is listed below along with a description of what
it displays. Some parameters may display information only
used by factory service personnel during diagnostic or repair.
It is not necessary to understand the function of each of these
parameters.