KEB COMBIVERT F5 Instruction Manual page 26

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Connection of the Power Circuit
Wiring diagram 3
1
Supply fuse
2
Disconnect switch or contactor
3
Line choke
4
Interference suppression filter
External motor temperature sensor
(for all units)
Don't install sensor wires with control wires!
Must use double shield when running these
wires with motor wires!
It is necessary to activate this function via
software parameter! See US.33
Connection of braking resistor
(Braking circuit installed as standard in
housing sizes E,G,H, R and U.)
Braking resistor
with line side over
temperature cutoff
This is the only way to turn
off voltage to the resistor in
the event of failure of the
internal braking transistor of
the inverter.
26
��
��
��
��
��
��
���
���
��
��
No jumper required, when
a sensor is not connected
24VDC or 120VAC contactor control voltage
Note: a NC thermal switch not PTC device on the resistor is required.
��
��
��
��
��
���
���
����� ��
5
COMBIVERT F5
6
Motor choke or output filter
7
Motor
8
Sub panel in control cabinet
��
��
Thermal switch
(NC-contact)
PA
PB
use with wiring diagram 2
������
���
���
��
��
��
���
��
��
Temperature sensor (PTC )
1650Ω...4kΩ tripping resistance
750Ω...1650Ω reset resistance
++
PB
use with wiring diagram 1
���
��
����
��
��
��
��
��
��
��
� �

Hide quick links: