Input/Output Configuration
9.2 Digital Output
Parameters
do. 42
Can be used to invert the function of the output. As an example, normally on
becomes normally off. Each output is assigned a value. To invert the output set
Output
this parameter to that value. To invert more than one output set this parameter to
Inversion
the sum of the values. Example X2A.18 = 1 and X2A.1 = 2, to inverter both set
this parameter equal to 3.
do.80
This parameter determines the function of the +24VDC solid state drive output
X2A.18. The function can be selected from the table on the following page.
Output
X2A.18
do.81
This parameter determines the function of the +24VDC solid state drive output
X2A.1. The function can be selected from the table on the following page.
Output
X2A.19
do.82
This parameter determines the function of the relay output X2A.24..26. The function
can be selected from the table on the following page.
Output
X2A.24..26
do.83
This parameter determines the function of the relay output X2A.27..2. The function
can be selected from the table on the following page.
Output
X2A.27..29
142
The digital output parameters can be used to configure the digital
outputs for operation. Normally these parameters only need to be
adjusted by the Elevator control builder.
Value
Output Terminal
1
X2A.18 +24VDC solid state output
2
X2A.1 +24VDC solid state output
4
X2A.24..26 form C relay output
8
X2A.27..2 form C relay output
Unit: -
Value Range: 0...15
Factory Setting: 0
Factory Setting: ASd
Factory Setting: FLt
Factory Setting: rdy
Factory Setting: dro