Parameter Description - Control Settings
Open loop torque boost
Switching frequency
Adjusts the torque boost only during open loop operation
(LF.30=0). If the torque boost is too low the motor may not be
able to lift the load. Too much boost can lead to high current
while running open loop.
Unit:
Value range:
Default setting:
Adjustment value:
Using parameter LF.38 the switching frequency of the inverter can
be set. The switching frequency can be constantly 8 kHz or 16kHz
with an automatic reduction based on the heat-sink temperature.
i
If the display often shows the error message E.OL2, then this
parameter should be set to zero. Some power stages only sup-
port 8Khz. On these units it is not possible to change to this
value.
Unit:
Value range:
Default setting:
Adjusted value:
% of input voltage
0.0...25.5 %
5.0 %
dependent on load
1
0 = switching frequency constantly 8 kHz
1 = 16kHz with automatic reduction
0
as needed