Parameter Description - Basic Set Up
6.2 LF-Elevator Parameters
Signal / operating mode
72
This value determines the type of speed selection and rotation
setting.
AbSPd
Value range:
d SPd
A tor
A SPd
SErSP
bnSPd
Default setting:
bnSPd
Value
Control mode
Abs. Analog Spd. Control
AbSPd
0...+10V terminals
X2A.1, X2A2
Digital Speed Control
d SPd
terminals X2A.10, X2A.11, X2A.15
X2A.12,X2A.13
Analog Torque Control
A tor
-10V...0... +10V terminals
X2A.1, X2A2, X2A.3, X2A4
Analog Speed Control
A SPd
-10V...0...+10V terminals
X2A.1, X2A2
Digital Serial Speed Control
SErSP
Serial communication
16 bit signed speed value
Binary Speed Control
bnSPd
terminals X2A.11,
X2A.12, X2A.13
When LF.2 = A tor then: max. system speed is approximately 110% of
(LF.20)
When LF.2 = AbSPd or A SPd then: 0 ... ±10V = 0 ... ± max. system speed
(LF.20)
= Absolute Analog Speed
= Digital Speed Selection
= Analog Torque Control
= Analog Speed Control
= Serial Com. Speed Control
= Binary Speed Selection
Direction Selection
terminals X2A.14 &
X2A.15
terminals X2A.14,
terminal X2A.14,
does not determine direction
used only for triggering the
start sequence
terminals X2A.14 &
X2A.15
do not determine
U
direction.
sed only for
triggering the start sequence
Serial communication
16 bit control word
terminals X2A.14,
X2A.15