Active Motor Power; Peak Motor Speed; Magnetizing Current - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Advanced Parameters
ru.81
This is the actual electrical power going to the motor. A negative value means power
being generated by the motor.
Active Motor
Power
Units: kW
ru.85
Displays the peak speed as measured by the motor encoder. Can be rest by pressing
the down arrow key or after power off.
Peak Motor
Speed
Units: rpm
ru.87
Only for Induction motors, displays the actual magnetizing current. The value will
drop as contract speed is reached because the flux controller is adjusting for field
Magnetizing
weakening.
Current
Units: amps rms
i
All remaining ru parameters are not important for the function of the elevator drive
and therefore are not documented here.
130