Power Module Temperature; Overload Counter; Power On Counter; Run Counter - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

ru.38
This is the temperature of the output transistors.
Power module
Units: °C
temperature
ru.39
Overload counter display. Once the load of the drive goes above 100% this counter
begins to increment. IF the load drops below it decrements. If the Counter reaches
Overload
100 the drive will shut down with an E.OL error.
counter
ru.40
Power On counter counts the time while powered up.
Units: hours
Power on
counter
ru.41
Run counter counts the time actual providing power to the motor and running the
elevator.
Run counter
Units: hours
ru.42
This is the percent utilization of the DC bus voltage. 100% means the DC bus is
100% utilized and the output voltage is equal to the input voltage. If this value
Modulation
reaches 100% or goes above 100% as a result of over modulation, loss of control
grade
of the motor will occur.
Units: %
ru.43
Displays the value of an internal timer.
Timer 1
ru.44
Displays the value of an internal timer.
Timer 1
ru.45
This is the actual carrier frequency the drive is operating at. Under certain conditions
the drive may lower the carrier frequency in order to provide more current at low
Actual
frequencies.
switching
frequency
ru.46
Displays the motor temperature. This value is only valid when the motor has a KTY
thermal sensor installed and that sensor is connected to the T1/T2 terminals.
Motor
temperature
Units: °C
ru.54
Display the value of the internal position counter.
Position
counter
Units: counts