Output Flag State; Output Status; Active Parameter Set; Analog Pattern Raw - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

This is the state of the internal output flags. Multiple active flags result in the sum
ru.24
of the values.
Output flag
state
ru.25
This is the state of the actual outputs. Multiple active outputs result in the sum of
the values.
Output status
ru.26
This parameter display the active internal parameter set.
Active parameter
set
ru.27
This parameter displays the value of the actual pattern signal applied between
terminal X2A.1 and X2A.2. The value is in percent +/- 100.0% = +/- 10.00V. This
Analog pattern
value is unfiltered and unprocessed.
raw
Units: %
ru.28
This parameter displays the processed analog pattern value. Filters, offsets and
gains are applied to this value. Again 100.0% = 10.00V on the input.
Analog pattern
processed
Units: %
Diagnostic parameters
Flag
Value
0
1
1
2
2
4
3
8
4
16
5
32
6
64
7
128
Output
Function
X2A.18
At Speed
X2A.1
FLT
X2A.24...26 RDY
X2A.27...2 DRO
A
Software Link
B
Software Link
C
Software Link
D
Software Link
Value
1
2
4
8
16
32
64
128
127