6.8. THERE IS NO HEART FREQUENCY SIGNAL
6.8.1.
NO
Place correclty
Page 6.18
Forma Line BIKE FORMA (DDC5): Technical Assistance manual - rev. 1.1
HR R
(H
ECEIVER
EART
THERE IS NO HR
SIGNAL
(Chest Belt)
Check if it works properly using
a chest belt you are sure it's ok.
The problem solved?
NO
1
Check the SW and the groundin
of Receiver Board.
Problem persists?
YES
2
Check the proper functioning
of the Receiver Board.
Is proper placed?
R
B
)
ATE
AND
YES
Chest Belt
defective
NO
OK
YES
Check if the +5Vdc are at the
input of the Receiver Board.
Are them present?
NO
Check if the +5Vdc are at the
output of the ARM/CPU Board.
Are them present?
NO
ARM/CPU Board
defective.
Replace.
3
YES
Receiver Board
SI
defective.
Replace.
4
YES
SI
Replace the connecting
cable between the High
Kit and the Low Kit.
Continues on the next page...