Com.fault X; Display Errors - Technogym FORMA LINE BIKE FORMA DDC5 Series Technical Assistance Manual

Table of Contents

Advertisement

9.2.3.3.
COM.Fault
This is a counter which displays the number of serial communication errors between the high kit
and the low kit. It increases every time a communication error is detected. Move using the +/- keys
of the difficulty level until the display shows:
To reset the counter, press ENTER and the display will show:
press ENTER to reset. Return to the upper level by pressing CANCEL for a few seconds.
9.2.3.4.

Display errors

The errors log provides a series of information as listed in the following table for every error
generated by the equipment.
• Error Code,
• Type of error,
• Current at the time of the error
• Distance in Km at the time of the error.
During movement, the Brake Board is capable of detecting possible faults. The possible detected
errors are:
Error Code
OVERTEMPERATURE: this condition occurs when the temperature measured
1
by the board sensor exceeds 90°C.
OVERVOLTAGE: this condition occurs when the voltage +12Vdc exceeds
8
13.7Vdc (only on powered models).
You move on to the subsequent error by pressing the + key of the difficulty level. Otherwise the
message containing the data of the current error is displayed again.
Page 9.14
Forma Line BIKE FORMA (DDC5): Technical Assistance manual - rev. 1.1

COM.FAULT X

RESET COM.FAULT?
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents