Technogym FORMA LINE BIKE FORMA DDC5 Series Technical Assistance Manual page 51

Table of Contents

Advertisement

Forma Line BIKE FORMA (DDC5): Technical Assistance manual - rev. 1.1
Follow the chart step by step in order to make a correct diagnosis. In particular, pay attention to
the checks highlighted in the numbered boxes and listed here below:
(1)
Carry out the Standard Settings, as described in the paragraph: "STANDARD SETTINGS".
(2)
Mains-powered equipment:
The speed signal can also be measured in a qualitative manner using a multimeter.
When the equipment is stationary, you should register a value of 0Vdc, which will
tend to grow as the speed increases.
With mains-powered equipment, the Speed Sensor detects the heads of the screws
that fix the copper disk to the flywheel (this is valid for all pieces of equipment except
Crossover, which also has the disk fixing screws, but the speed measurement is
performed on other screws fixed on the flywheel).
(3)
Perform a Low Kit SW Update, by first loading the Firmware (FW) and then the Brake
Table. At the end of the operation, launch the Standard Settings, to update the Low Kit
parameters.
Insert the tips of the tester on the ends of the speed sensor. If
you have an oscilloscope, the signal that should be
measured is like the one indicated in Figure 3.8-1, at about
80rpm user.
Page 6.17