Automatic Tests; I2C Devices Test - Technogym FORMA LINE BIKE FORMA DDC5 Series Technical Assistance Manual

Table of Contents

Advertisement

Forma Line BIKE FORMA (DDC5): Technical Assistance manual - rev. 1.1
AUTOMATIC TEST
Use the ENTER key to scroll from one parameter to another saving the data if
modified, whereas with the + and – speed keys, you can scroll from one parameter to
another without saving data; to cancel the operation, press the CANCEL key for a
few seconds.
The available tests are split into two groups: Automatic and Manual, and the choice is proposed as
soon as the troubleshooting menu is accessed.
6.1.1.
The tests that the equipment proposes in this section perform checks in a wholly automatic manner.
After selecting the item for the test you require by using the + and - difficulty level keys, you activate it
by pressing the ENTER key and wait for the result. Press ENTER again in order to continue and use
the CANCEL key to return to the superior level, by holding it down for a few seconds.
The various tests are detailed below:
6.1.1.1.

I2C Devices Test

The I2C Devices test is used to test the connection with the 32K and 256K memories.
The test can have the following results:
• "Test Successful, press Enter to continue": It means that the transmission and reception of
data packs by the I2C devices to the Display Board were successful.
• "EEPROM Error, press Enter to continue": It means that the Display Board has some
communication problems with the memories.
TROUBLESHOOTING
I2C Dev ices Test
LED Test
SERIAL PORTS
TEST
A
T
UTOMATIC
ESTS
MANUAL TEST
MAN.KEYBOARD
TEST
TGS COM Test
Low Kit COM Test
CSaf e COM Test
Page 6.3