Parameter
Introduction
x.00
description format
10

Advanced parameter descriptions

10.1

Overview

Table 10-1 Menu descriptions
Menu no.
1
Frequency / speed reference
2
Ramps
3
Frequency I/O, speed feedback and speed control
4
Current control
5
Motor control
6
Sequencer and clock
7
Analog I/O
8
Digital I/O
9
Programmable logic, motorized pot and binary sum
10
Status and diagnostics
11
General drive set-up
12
Threshold detectors and variable selectors
14
User PID controller
15*
Solutions module parameters
18
Application menu 1
20
Application menu 2
21
Second motor parameters
*Only appears when a solutions module is installed to the Commander SK.
Table 10-2 gives a full key of the coding which appears in the following parameter tables.
Table 10-2 Key to parameter coding
Coding
Bit
1 bit parameter
SP
Spare: not used
Filtered: some parameters which can have rapidly changing
FI
values are filtered when displayed on the drive keypad for
easy viewing.
Destination: indicates that this parameter can be a
DE
destination parameter.
Txt
Text: the parameter uses text strings instead of numbers.
VM
Variable maximum: the maximum of this parameter can vary.
Decimal place: indicates the number of decimal places used
DP
by this parameter.
No default: when defaults are loaded (except when the drive
ND
is manufactured or on EEPROM failure) this parameter is not
modified.
Rating dependant: this parameter is likely to have different
values and ranges with drives of different voltage and current
RA
ratings. These parameters are not transferred by SmartStick
when the rating of the destination drive is different from the
source drive.
Not copied: not transferred to or from SmartStick during
NC
copying.
NV
Not visible: not visible on the keypad.
PT
Protected: cannot be used as a destination.
User save: saved in drive EEPROM when the user initiates a
US
parameter save.
RW
Read/write: can be written by the user.
Bit default one/unsigned: Bit parameters with this flag set to
one have a default of one (all other bit parameters have a
BU
default of zero. Non-bit parameters are unipolar if this flag is
one.
Power-down save: automatically saved in drive EEPROM at
PS
power-down.
Commander SK Advanced User Guide
Issue Number: 9
Parameter
Keypad and
display
communications
Description
Attribute
www.controltechniques.com
Serial
CT Modbus
PLC Ladder
RTU
programming
Advanced parameter
CTSoft
Menu 0
descriptions
33

Hide quick links:

Advertisement

Table of Contents
loading