Parameter
Parameter
Introduction
x.00
description format
8.16
Unused parameter
8.17

Status relay invert

Bit
SP
Coding
1
Range
OFF(0) or On(1)
Default
OFF(0
Update rate
2 ms
Setting this parameter to On(1) causes the relay sense to be inverted.
8.18 to 8.19
Unused parameters
8.20

Digital I/O read word {90}

Bit
SP
Coding
Range
0 to 95
Update rate
Background
This word is used to determine the status of the digital I/O by reading one parameter.
Pr 8.20 contains a binary value 'xx'. This binary value is determined by the state of Pr 8.01 to Pr 8.07. So for example, if all terminals were active the
value displayed in Pr 8.20 would be the sum of the binary values shown in the table, i.e. 95.
Binary value
Digital I/O
for xx
1
Terminal B3
2
Terminal B4
4
Terminal B5
8
Terminal B6
16
Terminal B7
64
Terminal T5/T6
8.21
Terminal B3 digital input destination/output source
8.22
Terminal B4 digital input destination
8.23
Terminal B5 digital input destination
8.24
Terminal B6 digital input destination
8.25
Terminal B7 digital input destination
Bit
SP
Coding
Destination: Pr 0.00 to Pr 21.51
Range
Source: Pr 0.00 to Pr 21.51
Update rate
Read on drive reset
Parameter
8.21
Terminal B3 digital input destination/output source
8.22
Terminal B4 digital input destination
8.23
Terminal B5 digital input destination
8.24
Terminal B6 digital input destination
8.25
Terminal B7 digital input destination
The terminal configuration for Terminal B4, B5 and B6 can be changed using Pr 6.04.
Destination parameters define the parameter each of the programmable inputs is to control. Only parameters which are not protected can be
controlled by the programmable digital inputs. If a non-valid parameter is programmed, the digital input is not routed anywhere.
Source parameters define the parameter to be represented by the digital output terminal. Only valid parameters can be selected as a source for a
digital output. If a non-valid parameter is programmed, then the digital output will remain in the inactive state.
8.26
Unused parameter
Commander SK Advanced User Guide
Issue Number: 9
Keypad and
Serial
display
communications
FI
DE
Txt VM DP ND
FI
DE
Txt VM DP ND
1
FI
DE
Txt VM DP ND
1
2
Function
www.controltechniques.com
CT Modbus
PLC Ladder
RTU
programming
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
1
Default Setting
10.03
Zero Speed (Output)
6.29
6.30
6.32
1.41
Reference select
Advanced parameter
CTSoft
Menu 0
descriptions
PS
PS
1
PS
1
Description
Enable
Run forward
Run Reverse
Menu 8
115