Advanced Parameter Descriptions; Overview; Menu Descriptions; Key To Parameter Coding - Emerson unidrive sp User Manual

Universal variable speed ac drive for induction and servo motors
Hide thumbs Also See for unidrive sp:
Table of Contents

Advertisement

Parameter
Keypad and
Parameter x.00
structure
display
5
Advanced parameter
descriptions
5.1

Overview

Table 5-1 Menu descriptions
Menu no.
1
Frequency / speed reference
2
Ramps
3
Slave frequency, speed feedback and speed control
4
Torque and current control
5
Motor control
6
Sequencer and clock
7
Analog I/O
8
Digital I/O
9
Programmable logic, motorized pot and binary sum
10
Status and trips
11
General drive set-up
12
Threshold detectors, variable selectors and brake control
13
Position control
14
User PID controller
15, 16, 17 Solutions Module slots
18
Application menu 1
19
Application menu 2
20
Application menu 3
21
Second motor parameters
22
Additional menu 0 set-up
Table 5-2 gives a full key of the coding which appears in the following
parameter tables.
26
Parameter
Advanced parameter
description format
descriptions
Description
www.controltechniques.com
Serial comms
Macros
protocol
Table 5-2 Key to parameter coding
Coding
Bit
1 bit parameter
SP
Spare: not used
Filtered: some parameters which can have rapidly changing
FI
values are filtered when displayed on the drive keypad for
easy viewing.
Destination: indicates that this parameter can be a
DE
destination parameter.
Txt
Text: the parameter uses text strings instead of numbers.
VM
Variable maximum: the maximum of this parameter can vary.
Decimal place: indicates the number of decimal places used
DP
by this parameter.
No default: when defaults are loaded (except when the drive
ND
is manufactured or on EEPROM failure) this parameter is not
modified.
Rating dependent: this parameter is likely to have different
values and ranges with drives of different voltage and current
ratings. Parameters with this attribute will not be transferred
to the destination drive by SMARTCARDs when the rating of
RA
the destination drive is different from the source drive and the
file is a parameter file. However, with software V01.09.00 and
later the value will be transferred if only the current rating is
different and the file is a differences from default type file.
Not copied: not transferred to or from SMARTCARDs during
NC
copying.
NV
Not visible: not visible on the keypad.
PT
Protected: cannot be used as a destination.
User save: saved in drive EEPROM when the user initiates a
US
parameter save.
RW
Read/write: can be written by the user.
Bit default one/unsigned: Bit parameters with this flag set to
one have a default of one (all other bit parameters have a
BU
default of zero. Non-bit parameters are unipolar if this flag is
one.
Power-down save: parameter automatically saved in drive
EEPROM when the under volts (UV) trip occurs.
PS
With software version V01.08.00 and later, power-down
save parameters are also saved in the drive when the user
initiates a parameter save.
Electronic
Performance
RFC mode
nameplate
Attribute
Unidrive SP Advanced User Guide
Issue Number: 10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents