Brake Control Function; Brake Release Indicator; Brake Controller Enable - Emerson 2202 Advanced User's Manual

Commander sk series ac variable speed drive for 3 phase induction motors from 0.25kw to 110kw, 0.33hp to 150hp
Table of Contents

Advertisement

Parameter
Parameter
Introduction
x.00
description format
10.13.1

Brake control function

The brake control functions are provided to allow well co-ordinated operation of an external brake with the drive. While both hardware and
software are designed to high standards of quality and robustness, they are not intended for use as safety functions, i.e. where a fault or
failure would result in a risk of injury. In any application where the incorrect operation of the brake release mechanism could result in injury,
independent protection devices of proven integrity must also be incorporated.
WARNING
The brake control function can be used to control an electro-mechanical brake via the drive digital I/O.
12.40

Brake release indicator

Bit
SP
Coding
1
Range
OFF(0) or On(1)
Update rate
21 ms
This parameter should be used as a source for a digital output to control an electro-mechanical brake. This parameter is one to release the brake and
zero to apply the brake. Digital I/O can be automatically configured to use this parameter as a source (see Pr 12.41).
12.41

Brake controller enable {12}

Bit
SP
Coding
Range
diS(0), rEL(1), d IO(2), USEr(3)
Default
diS(0)
Update rate
Actioned on exit of edit mode or drive reset
Action will only occur if the drive is inactive. If the drive is active the parameter will return to its pre altered value on exit from edit mode or drive reset.
0
diS
The brake controller is disabled and no other drive parameters are affected by the brake controller. When this parameter is changed from a non-zero
value to zero Pr 2.03 is set to zero.
1
rEL
The brake controller is enabled with I/O set up to control the brake via the relay output. Drive ok is re-routed to digital I/O.
2
d IO
The brake controller is enabled with I/O set up to control the brake via digital I/O.
3
USEr
The brake controller is enabled, but no parameters are set to select the brake output.
The following table shows the automatic parameter changes that occur to set up digital I/O and the relay output after exit from edit mode or drive reset
when Pr 12.41 has been changed.
Old value of
New value of
Pr 12.41
Pr 12.41
Any
1
Not 1
2
1
2
1
0 or 3
2
0 or 3
Ensure that the brake controller is setup correctly before the electro-mechanical brake circuit is connected to the drive. Disconnect the
electro-mechanical brake circuit before a default is performed.
WARNING
Commander SK Advanced User Guide
Issue Number: 9
Keypad and
Serial
display
communications
FI
DE
Txt VM DP ND
1
FI
DE
Txt VM DP ND
1
Pr 8.11
Pr 8.21
Drive ok output
OFF
Pr 10.01
Brake release output
OFF
Pr 12.40
Brake release output
OFF
Pr 12.40
Zero speed output
OFF
Pr 10.03
Zero speed output
OFF
Pr 10.03
www.controltechniques.com
CT Modbus
PLC Ladder
RTU
programming
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
Pr 8.31
1
1
1
1
1
Advanced parameter
CTSoft
Menu 0
descriptions
PS
PS
1
Pr 8.17
Pr 8.27
Brake release output
OFF
Pr 12.40
No change
No change
Drive ok output
OFF
Pr 10.01
Drive ok output
OFF
Pr 10.01
No change
No change
Menu 12
Pr 8.41
3
8
8
0
0
161