Menu 6: Drive Sequencer And Clock - Emerson 2202 Advanced User's Manual

Commander sk series ac variable speed drive for 3 phase induction motors from 0.25kw to 110kw, 0.33hp to 150hp
Table of Contents

Advertisement

Parameter
Menu 6
Introduction
x.00
10.7

Menu 6: Drive sequencer and clock

Table 10-8 Menu 6 parameters: single line descriptions
Parameter
6.01
Stop mode select
6.02
Not used
6.03
Mains loss mode
6.04
Start/stop logic select
6.05
Not used
6.06
Injection braking level
6.07
Injection braking time
6.08
Not used
6.09
Catch a spinning motor select
6.10
Low DC bus operation*
6.11
Remote LED keypad function key status
6.12
Enable stop key
6.13
Function key mode
6.14
Disable auto reset on enable
6.15
Drive enable
6.16
Electricity cost per kWh
6.17
Reset energy meter
6.18
Not used
6.19
Not used
6.20
Not used
6.21
Not used
6.22
Run time log: years.days
6.23
Run time log: hours.minutes
6.24
Energy meter: MWh
6.25
Energy meter: kWh
6.26
Running cost
6.27
Not used
6.28
Not used
6.29
Hardware enable
6.30
Sequencing bit: Run forward
6.31
Sequencing bit: Jog forward
6.32
Sequencing bit: Run reverse
6.33
Sequencing bit: Fwd/Rev
6.34
Sequencing bit: Run
6.35
Forward limit switch
6.36
Reverse limit switch
6.37
Sequencing bit: Jog reverse
6.38
Not used
6.39
Sequencing bit: /Stop
6.40
Enable sequencer latching
6.41
Not used
6.42
Control word
6.43
Control word enable
6.44
Not used
6.45
Force cooling fan to run at full speed
* Only available on Commander SK size B, C and D.
** On with USA defaults.
84
Parameter
Keypad and
description format
display
communications
{31}
{11}
{33}
www.controltechniques.com
Serial
CT Modbus
PLC Ladder
RTU
programming
Range
0 to 4
diS(0), StoP(1), rd.th(2)
0 to 6
0.0 to 150.0%
0.0 to 25.0 s
0 to 3
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
0 to 6
OFF(0) or On(1)
OFF(0) or On(1)
0.0 to 600.0 currency/kWh
OFF(0) or On(1)
0.000 to 9.365 years.days
0.00 to 23.59 hours.minutes
0.0 to 999.9 MWh
0.00 to 99.99 kWh
±32000 currency/hour
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
OFF(0) or On(1)
0 to 32767
OFF(0) or On(1)
OFF(0) or On(1)
Advanced parameter
CTSoft
Menu 0
Default
Setting
1
diS(0)
0 (Eur)
4 (USA)
100.0
1.0
0
OFF(0)
OFF(0)
OFF(0)**
0
OFF(1)
On(1)
0.0
OFF(0)
OFF(0)
OFF(0)
OFF(0)
OFF(0)
OFF(0)
OFF(0)
OFF(0)
OFF(0)
OFF(0)
OFF(0)
OFF(0)
0
OFF(0)
OFF(0)
Commander SK Advanced User Guide
Issue Number: 9
descriptions
Update Rate
2 ms
2 ms
Edit mode exit
B
2 ms
B
B
B
B
BR
2 ms
2 ms
B
B
B
B
B
B
B
2 ms
2 ms
2 ms
2 ms
2 ms
2 ms
2 ms
2 ms
2 ms
2 ms
2 ms
2 ms
2 ms
B