Emerson Advantage 2.1 Installation, Operation And Maintenance Manual

Emerson Advantage 2.1 Installation, Operation And Maintenance Manual

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Advantage 2.1

  • Page 3: Table Of Contents

    Tighten the bonnet fasteners ....................10 Fastener torque table for valve body to topworks ..............11 Actuator operating pressure ....................11 Disassemble the valve ......................11 Replace the valve diaphragm ....................11 Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 4: Introduction And Safety

    The operating company must do the following tasks: • Define the responsibilities and competency of all personnel handling this equipment. • Provide instruction and training. Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 5 If the identification tag is missing or worn, contact ASCO for specific instructions. Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 6: Transportation And Storage

    • Complete a Material Safety Data Sheet or Process Data Sheet for any process fluid that could remain on the valve. • Obtain a Return Material Authorization from the factory. Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 7: Product Description

    Description B308 Advantage 2.1 actuator, double acting, series 8 B216 Advantage 2.1 actuator, fail close, series 16 with a spring set For fail close actuators, codes are specific spring combinations. Series number equates to diaphragm effective area. Advantage 2.1 Actuator Installation and Operation Manual...
  • Page 8: Bonnet Description

    All diaphragm materials and physical properties are batch traceable via permanent codes molded into the diaphragm tabs. The molding date, grade of diaphragm, and size provide traceability to original batch records. Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 9 2. Supplier code Figure 5: Elastomer diaphragm front 1. Valve size 2. Grade of diaphragm Figure 6: Elastomer diaphragm back 1. Material code 2. Date code Figure 7: PTFE diaphragm Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 10: Installation

    Consider the following information before installing the actuator: • The series 3, 5, 8, or 16 stainless steel bonnet Advantage 2.1 actuator can have the air inlets positioned in any quadrant. • The maximum valve operating pressure is 10.34 bar | 150 psig. This pressure is applicable up to 38ºC | 100ºF.
  • Page 11: Change The Compressor, Tube Nut, And Snap Ring

    1. Insert a screw driver or similar thin blade between compressor and bonnet flange. Figure 8: Remove the compressor 2. Apply light pressure to back side of compressor finger. 3. Remove compressor and snap ring assembly. Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 12: Mount The Topworks To The Valve

    Depressurize the system and retighten the bonnet fasteners as sealing area noted above. Continues Depressurize the system and retighten the bonnet fasteners as noted above. (maximum 3rd re-torque) Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 13: Fastener Torque Table For Valve Body To Topworks

    Replace the valve diaphragm 1. Disassemble the valve. For more information, see Disassemble the valve (page 11). 2. Unscrew the diaphragm from the compressor by turning the diaphragm counterclockwise. Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 14 Engage the threads of the diaphragm into the tube nut by rotating clockwise. d) Continue rotating the PTFE diaphragm clockwise into the compressor while securing the backing cushion from rotating. Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 15 7. For more information, see Tighten the bonnet fasteners (page 10). 8. If the actuator mode of operation is fail open, then release the air, allowing the valve to open. Advantage 2.1 Actuator Installation and Operation Manual Designed and Manufactured by ITT...
  • Page 16 Visit our website for the latest version of this document and more information: www.emerson.com United Kingdom Customer Service Sales Admin 44-(0)1695-71 36 14 enquiries.asco.uk@emerson.com France: Sales Admin: 02 37 24 47 76 anf .serviced ients@emerson.com Italy +39 02 95037010 ANS .AFTERSALES@Emerson.com Netherlands +31332777805 info.asco.nl@emerson.com Spain +34 942 876 101 ventas.ane@emerson.com...

Table of Contents