Parameter
Parameter
Introduction
x.00
description format
Table 10-23 Parameter changes when drive configuration is changed
Parameter
Description
number
71
Configurable parameter 1 set-up
72
Configurable parameter 2 set-up
73
Configurable parameter 3 set-up
74
Configurable parameter 4 set-up
75
Configurable parameter 5 set-up
76
Configurable parameter 6 set-up
77
Configurable parameter 7 set-up
78
Configurable parameter 8 set-up
79
Configurable parameter 9 set-up
80
Configurable parameter 10 set-up
1.14
Reference select
6.04
Start/stop logic
7.06
Analog input 1 mode
7.11
Analog input 2 mode
7.14
Analog input 2 destination
8.15
Terminal B7 digital input invert
8.22
Terminal B4 digital input destination
8.25
Terminal B7 digital input destination
9.25
Motorized pot destination
14.03
PID reference source
14.04
PID feedback source
14.16
PID destination
NOTE
1. If last default setting was Eur, then Pr 6.04 is 0. If last default setting was USA, then Pr 6.04 is 4 except in HVAC mode where Pr 6.04 is 0.
NOTE
2. If last default setting was Eur, then Pr 8.22 is 6.29. If last default was USA, then Pr 8.22 is 6.39 except in PAd or HVAC mode where Pr 8.22 is
6.29.
Pr 11.27
Configuration
0
AI.AV
1
AV.Pr
2
AI.Pr
3
Pr
4
PAd
5
E.Pot
6
tor
7
Pid
8
HVAC
Commander SK Advanced User Guide
Issue Number: 9
Keypad and
Serial
display
communications
AI.AV
0
Note 1
4
0
Pr 1.37
1
Note 2
Pr 1.41
0
0
0
0
Description
Voltage and current input
Voltage input and 3 preset speeds
Current input and 3 preset speeds
4 preset speeds
Keypad control
Electronic motorized potentiometer control
Torque control operation
PID control
Fan and pump control
www.controltechniques.com
CT Modbus
PLC Ladder
RTU
programming
Drive Configuration
AV.Pr
AI.Pr
Pr
1
1
3
Note 1
Note 1
Note 1
6
4
6
1
1
1
Pr 1.46
Pr 1.46
Pr 1.46
0
0
0
Note 2
Note 2
Note 2
Pr 1.45
Pr 1.45
Pr 1.45
0
0
0
0
0
0
0
0
0
0
0
0
Advanced parameter
CTSoft
Menu 0
descriptions
PAd
E.Pot
tor
Pr 9.23
Pr 9.22
Pr 9.21
4
3
0
Note 1
Note 1
Note 1
6
6
4
0
1
0
Pr 1.37
Pr 9.27
Pr 4.08
1
0
0
Pr 6.29
Note 2
Note 2
Pr 1.41
Pr 9.26
Pr 4.11
0
Pr 1.21
0
0
0
0
0
0
0
0
0
0
Menu 11
Pid
HVAC
Pr 14.10
Pr 14.11
Pr 14.06
Pr 14.13
Pr 14.14
Pr 14.01
2
0
Note 1
0
4
4
0
0
0
Pr 1.37
0
1
Note 2
Pr 6.29
Pr 14.08
Pr 1.43
0
0
Pr 7.02
0
Pr 7.01
0
Pr 1.37
0
141