Parameter
Introduction
x.00
description format
7

PLC Ladder programming

PLC Ladder programming and SYPTLite
The Commander SK has the ability to store and execute a 3kb PLC ladder logic program.
NOTE
To enable the Commander SK to store and execute a SYPTLite program, a LogicStick must be installed to the drive.
The ladder logic program is written using SYPTLite, a Windows based ladder diagram editor allowing the development of programs for execution in
the Commander SK.
SYPTLite is designed to be easy to use and to make program development as simple as possible. SYPTLite programs are developed using ladder
logic, a graphical language widely used to program PLCs (IEC 61131-3). SYPTLite allows the user to 'draw' a ladder diagram representing a program.
SYPTLite provides a complete environment for the development of ladder diagrams. Ladder diagrams can be created, compiled into PLC ladder
programs and downloaded into the Commander SK for execution via the RJ45 serial communications port on the front of the drive. The run-time
operation of the compiled ladder diagram on the target can also be monitored using SYPTLite and facilities are provided to interact with the program
on the target by setting new values for target parameters.
SYPTLite is available on the CD which is provided with the drive. The LogicStick can be purchased from your local Control Techniques Drive Centre
or Distributor.
Benefits
The combination of the PLC ladder program and SYPTLite mean that Commander SK can replace nano and some micro PLC's in many applications.
A Commander SK ladder program can contain up to 50 ladder logic rungs, up to 7 function blocks and 10 contacts per rung. The ladder program will
be stored on the LogicStick.
In addition to the basic ladder symbols, SYPTLIte contains:
Arithmetic blocks
Comparison blocks
Timers
Counters
Multiplexers
Latches
Bit manipulation
Typical applications of the PLC ladder program include:
Ancillary pumps
Fans and control valves
Interlocking logic
Sequences routines
Custom control words
Limitations
The PLC ladder program has the following limitations:
The maximum program size is 3kbytes including the header and optional source code
The user cannot create user variables. If they are needed, the user must use free registers in menus 18 and 20. The PLC ladder program can
manipulate any drive parameter except parameters in menu 0.
The program is only accessible via the drive's RJ45 serial communications port.
There are no real-time tasks i.e. the scheduling rate of the program cannot be guaranteed. The PLC ladder programming should not be used for
time critical applications.
NOTE
The LogicStick is rated for 1,000,000 downloads. The LogicStick can be transferred from one drive to another or a fresh copy of a PLC ladder
program can be made on a different LogicStick by downloading the program from SYPTLite.
User program performance
Programs run at a low priority. The Commander SK provides a single background task in which to run the ladder diagram. The drive is prioritised to
perform its major functions first e.g. motor control, and will use any remaining processing time to execute the ladder diagram. As the drive's processor
becomes more heavily loaded running its major functions, less time is spent executing the program. SYPTLite displays the average execution time
calculated over the last 10 scans of the user program.
Getting started and system requirements
SYPTLite can be found on the CD which is supplied with the drive.
Commander SK LogicStick
Windows 2000/XP/Vista 32 required. Windows 95/98/98SE/ME/NT4 are not supported.
Internet explorer V5.0 or later must be installed
Minimum of 800x600 screen resolution with 256 colors
128MB RAM
Pentium III 500MHz or better recommended
Adobe Acrobat 5.10 or later (for parameter help)
RS232 to RS485, RJ45 communications lead to connect the PC to the Commander SK
NOTE
The user must have administrator rights under Windows 2000/XP/Vista 32 to install the software.
24
Parameter
Keypad and
display
communications
www.controltechniques.com
Serial
CT Modbus
PLC Ladder
RTU
programming
Advanced parameter
CTSoft
Menu 0
descriptions
Commander SK Advanced User Guide
Issue Number: 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents