Pr 61-70 Set-Up; Customer Defined Scaling; Parameter Displayed At Power-Up; Serial Comms Address - Emerson 2202 Advanced User's Manual

Commander sk series ac variable speed drive for 3 phase induction motors from 0.25kw to 110kw, 0.33hp to 150hp
Table of Contents

Advertisement

Parameter
Parameter
Introduction
x.00
description format
11.01
Pr 61 set-up {71}
11.02
Pr 62 set-up {72}
11.03
Pr 63 set-up {73}
11.04
Pr 64 set-up {74}
11.05
Pr 65 set-up {75}
11.06
Pr 66 set-up {76}
11.07
Pr 67 set-up {77}
11.08
Pr 68 set-up {78}
11.09
Pr 69 set-up {79}
11.10
Pr 70 set-up {80}
Bit
SP
Coding
Range
Pr 1.00 to Pr 21.51
Default
Pr 0.00
Update rate
Background
These parameters define the parameters that reside in the programmable area in level 2 of the basic parameter set.
11.11 to 11.20
Unused parameters
11.21

Customer defined scaling {24}

Bit
SP
Coding
Range
0.000 to 9.999
Default
1.000
Update rate
Background
When customer defined units are selected as the display units this parameter is used to scale the RPM (Pr 5.04) to give the displayed units. See
Pr 5.34 on page 82.
NOTE
When speeds greater than 9999 rpm are to be displayed, set Pr 11.21 to 0.1 or 0.01.
Example:
Maximum speed of 30000 rpm. Set Pr 11.21 to 0.1, 30000 rpm = 3000 on display
11.22

Parameter displayed at power-up

Bit
SP
Coding
1
Range
OFF(0) or On(1)
Default
OFF(0)
Update rate
N/A
0: OFF Frequency (Pr 2.01)
1: On
Percentage load (Pr 4.20)
This parameter defines which parameter is displayed at power-up, either the speed or the load. This parameter is written to automatically when the
user switches between speed and load indications in parameter status mode by holding the Mode button down for a period of 2 seconds. In this case
the parameter is saved automatically by the drive, if the user changes this parameter using serial communication it is not saved automatically.
11.23

Serial comms address {44}

Bit
SP
Coding
Range
0 to 247
Default
1
Update rate
Background
This parameter is used to define the unique address for the drive for the serial interface. The drive is always a slave.
Commander SK Advanced User Guide
Issue Number: 9
Keypad and
Serial
display
communications
FI
DE
Txt VM DP ND
2
FI
DE
Txt VM DP ND
3
FI
DE
Txt VM DP ND
FI
DE
Txt VM DP ND
www.controltechniques.com
CT Modbus
PLC Ladder
RTU
programming
RA
NC
NV
PT
US RW BU
1
1
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
RA
NC
NV
PT
US RW BU
1
1
Advanced parameter
CTSoft
Menu 0
descriptions
PS
1
PS
1
PS
PS
1
Menu 11
139