Parameter Descriptions - Emerson Unidrive M400 User Manual

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M400:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
6.2

Parameter descriptions

6.2.1
Pr mm.000
Pr mm.000 is available in all menus, commonly used functions are provided as text strings in Pr mm.000 shown in Table 6-1. The functions in Table
6-1 can also be selected by entering the appropriate numeric values (as shown in Table 6-2) in Pr mm.000. For example, enter 7001 in Pr mm.000 to
store drive parameters on an NV media card.
Table 6-1 Commonly used functions in xx.000
Equivalent
Value
value
0
0
1000
1
Save Parameters
6001
2
Load file 1
4001
3
Save to file 1
6002
4
Load file 2
4002
5
Save to file 2
6003
6
Load file 3
4003
7
Save to file 3
12000
8
Show non-default
12001
9
Destinations
1233
10
Reset 50 Hz defs
1244
11
Reset 60 Hz defs
1070
12
Reset modules
Table 6-2 Functions in Pr mm.000
Value
1000
Save parameters when Under Voltage Active (Pr 10.016) is not active.
1001
Save parameter under all conditions
1070
Reset option module
1233
Load standard (50 Hz) defaults
1234
Load standard (50 Hz) defaults to all menus except option module menu 15
1244
Load US (60 Hz) defaults
1245
Load US (60 Hz) defaults to all menus except option module menu 15
1299
Reset {Stored HF} trip.
2001*
Create a boot file on a non-volatile media card based on the present drive parameters including all Menu 20 parameters
4yyy*
NV media card: Transfer the drive parameters to parameter file YYY
5yyy*
NV media card: Transfer the onboard user program to onboard user program file YYY
6yyy*
NV media card: Load the drive parameters from parameter file YYY or the onboard user program from onboard user program file YYY
7yyy*
NV media card: Erase file YYY
8yyy*
NV Media card: Compare the data in the drive with file YYY
9555*
NV media card: Clear the warning suppression flag
9666*
NV media card: Clear the warning suppression flag
9777*
NV media card: Clear the read-only flag
9888*
NV media card: Set the read-only flag
12000**
Only display parameters that are different from their default value. This action does not require a drive reset.
12001**
Only display parameters that are used to set-up destinations (i.e. DE format bit is 1). This action does not require a drive reset.
Backup all drive data (parameter differences from defaults, an onboard user program and miscellaneous option data), including the
40yyy
drive name; the store will occur to the </fs/MCDF/driveyyy/> folder; if it does not exist, it will be created. Since the name is stored, this
is a backup, rather than a clone. The command code will be cleared when all drive and option data have been saved.
Load all drive data (parameter differences from defaults, an onboard user program and miscellaneous option data); the load will come
60yyy
from the </fs/MCDF/driveyyy/> folder. The command code will not be cleared until the drive and all option data have been loaded.
* See Chapter 9 NV Media Card Operation on page 83 for more information on these functions.
** These functions do not require a drive reset to become active.
All other functions require a drive reset to initiate the function. To allow easy access to some commonly used functions, refer to the table overleaf.
Equivalent values and strings are also provided in the table above.
70
Electrical
Getting
Basic
installation
started
parameters
String
No Action
No action
Save drive parameters to non-volatile memory
Load the data from file 1 on a non-volatile media card into the drive provided it is a parameter file
Store the drive parameters in file 1 on a non-volatile media card
Load the data from file 2 on a non-volatile media card into the drive provided it is a parameter file
Store the drive parameters in file 2 on a non-volatile media card
Load the data from file 3 on a non-volatile media card into the drive provided it is a parameter file
Store the drive parameters in file 3 on a non-volatile media card
Only display parameters that are different from their default value
Only display parameters that are used to set-up destinations
Load 50 Hz defaults
Load 60 Hz defaults
Reset all option modules
Running
NV Media Card
Optimization
the motor
Operation
Action
Onboard
Advanced
Technical data Diagnostics
PLC
parameters
Action
Unidrive M400 User Guide
UL listing
information
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents