Variable Selector 1 Source 1/2; Variable Selector 1 Mode; Variable Selector 1 Destination; Variable Selector 1 Output - Emerson 2202 Advanced User's Manual

Commander sk series ac variable speed drive for 3 phase induction motors from 0.25kw to 110kw, 0.33hp to 150hp
Table of Contents

Advertisement

Parameter
Parameter
Introduction
x.00
description format
12.08
Variable selector 1 source 1
12.09
Variable selector 1 source 2
Bit
SP
Coding
Range
Pr 0.00 to Pr 21.51
Default
Pr 0.00
Update rate
Read on drive reset
These parameters and Pr 12.28 and Pr 12.29 define the parameters which are to be switched by the variable selector block. These can be bit
variables or non bit variables. If programming a reference to a variable source select, if the reference is a whole number, then the variable source
treats the whole number as a percentage, e.g. 5.0Hz = 10% of reference.
12.10

Variable selector 1 mode

Bit
SP
Coding
Range
0 to 9
Default
0
Update rate
21 ms
The output of the variable select can be changed by the mode as in the following table:
Mode value
Action
(Pr 12.10)
0
Select input 1
1
Select input 2
2
Add
3
Subtract
4
Multiply
5
Divide
6
Time constant
7
Linear ramp
8
Modulus
9
Raise to power
12.11

Variable selector 1 destination

Bit
SP
Coding
Range
Pr 0.00 to Pr 21.51
Default
Pr 0.00
Update rate
Read on drive reset
Defines the destination parameter for the variable selector 1 output. Only non-protected parameters can be programmed as a destination. If a non-
valid parameter is programmed, the output is not routed anywhere.
12.12

Variable selector 1 output

Bit
SP
Coding
Range
±100.0%
Update rate
21 ms
Indicates the level of output signal from the variable selector.
Commander SK Advanced User Guide
Issue Number: 9
Keypad and
Serial
display
communications
FI
DE
Txt VM DP ND
2
FI
DE
Txt VM DP ND
output = input1
output = input2
output = input1 + input2
output = input1 - input 2
output = (input1 x input2) / 100.0
output = (input1 x 100.0) / input2
output = input1 / ((control param)s + 1)
output = input1 via a ramp with a ramp time of (control param)
seconds from 0 to 100%
output = | input1 |
control param (0.01 - 0.03)
output = input1
control = 0.02: output = input1
control = 0.03: output = input1
control has any other value: output = input 1
FI
DE
Txt VM DP ND
1
2
FI
DE
Txt VM DP ND
1
1
www.controltechniques.com
CT Modbus
PLC Ladder
RTU
programming
RA
NC
NV
PT
US RW BU
1
1
1
RA
NC
NV
PT
US RW BU
1
1
Result
2
/ 100
3
2
/ 100
RA
NC
NV
PT
US RW BU
1
1
1
RA
NC
NV
PT
US RW BU
1
1
Advanced parameter
CTSoft
Menu 0
descriptions
PS
1
PS
1
PS
1
PS
Menu 12
157

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents