Sign In
Upload
Manuals
Brands
Emerson Manuals
Controller
Bettis SCE300
Emerson Bettis SCE300 Manuals
Manuals and User Guides for Emerson Bettis SCE300. We have
3
Emerson Bettis SCE300 manuals available for free PDF download: Installation, Operation And Maintenance Manual
Emerson Bettis SCE300 Installation, Operation And Maintenance Manual (67 pages)
Brand:
Emerson
| Category:
Controller
| Size: 7.66 MB
Table of Contents
Table of Contents
3
Section 1: General Safety Instructions
5
Intended Use
5
Terms and Conditions
6
Manufacturer's Liability
6
Identification
7
Water - Dust-Proof Version
7
Explosion-Proof Version
8
Applicable Standards and Regulations
10
Extract from the Standard
10
Manufacturer
10
Section 2: Machine Description
11
General
11
Principle of Operation
11
Electrical Operation
11
Manual Operation
12
Description of Main Parts
12
Optional Modules
13
Options Label
14
Section 3: Storage and Pre-Installation
15
Checks to be Carried out When the Actuator Is Received
15
Storage Procedure
15
General
15
Short-Term Storage (Less than One Year)
16
Long-Term Storage (more than One Year)
16
Section 4: Installation
17
Checks to be Performed before Installation
17
Working Condition
17
Mounting Base
18
Installation of the SCE300 Unit Onto a Valve
19
Manual Operation
20
Setting of the Angular Stroke: Mechanical Stops
21
Electrical Connections
22
Plant Requirements
23
Removal of the Terminal Board Enclosure
25
Cable Connections
26
Base Wiring Diagram
27
Cable Entries
28
Safety Instructions for Installation in Hazardous Areas
30
Instructions for Explosion-Proof Enclosures
30
Section 5: Lubrication
32
Lubrication Inspection
32
Section 6: Actuator Configuration
33
Removal of the Control Unit Cover
33
Local Configuration of the SCE300
34
SCE300 Default General Configuration
34
Close Limit Configuration by Position
37
Close Limit Configuration
37
Open Limit Configuration by Position
37
Open Limit Configuration
38
Close Limit Configuration by Torque
38
Open Limit Configuration by Torque
38
Stroking Time Selection in Closing
39
Stroking Time Selection in Opening
40
Setting of the Torque-Limiting Device in Closing
40
Configuration of the Torque Limiting Device in Opening
41
Reverse Mode Configuration
41
Actuator Model Selection
42
Blinker / Local Selector Configuration
44
Three-Wires (3-Wires) / Two-Wires (2-Wires) Remote Control Configuration
44
Configuration of the SCE300 Via PDA / PC and 'A Manager' Software
45
Hardware Configuration for Monitor Relay
45
Section 7: Maintenance and Troubleshooting
46
Maintenance
46
Routine Maintenance (Approximately Every Two Years)
46
Special Maintenance
47
Troubleshooting
47
The Electronics Do Not Switch on When Powered
47
24 V DC Output Voltage Not Available at the Terminals
48
The Actuator Does Not Work from Remote Controls
48
The Motor Is very Hot and Does Not Start
48
The Motor Runs but the Actuator Does Not Move the Valve
48
The Valve Does Not Seat Correctly
49
Excessive Torque for Valve Operation
49
The Actuator Does Not Stop in Fully Open or Fully Closed Position
49
Diagnostic LED
49
Section 8: Decommissioning
50
Disposal and Recycling
50
Advertisement
Emerson Bettis SCE300 Installation, Operation And Maintenance Manual (22 pages)
Local Interface Module
Brand:
Emerson
| Category:
Control Unit
| Size: 3.45 MB
Table of Contents
Table of Contents
3
Section 1: Optional Module 3: Local Interface Module
5
Local Interface Functionality
5
Manufacturer
6
Section 2: Assembling Procedure
7
Assembling Procedure
7
Section 3: Description of OM3 Local Interface
11
Local Operator Interface
11
Description of the Local Interface
12
2-Position Selector
12
Leds Indicating the Position of the SCE300 Actuator
12
OPEN/CLOSE Pushbuttons
12
Section 4: to Locally Operate the Actuator
13
To Locally Operate the Actuator
13
Section 5: OM3 Wiring Diagram
14
OM3 Wiring Diagram
14
Section 6: Identification
15
Water-, Dust-Proof Version
15
Label for Application in Water-, Dust-Proof Areas
15
Explosion-Proof Version
16
ATEX Label for Application in Hazardous Areas
16
Section 7: Safety Instructions
17
Foreword
17
General Safety Instructions
17
Check for Right Application
17
Applicable Standards and Regulations
18
Terms and Conditions
18
Manufacturer's Liability
18
Section 8: Installation
19
Working Conditions
19
Electrical Connections
19
Instructions for the Intrinsically-Safe Enclosures
19
Installation in Ambient with Explosive Dusts
19
Section 9: Special Maintenance
20
Periodic Inspections
20
Repairs of Intrinsically-Safe Parts
20
Emerson Bettis SCE300 Installation, Operation And Maintenance Manual (22 pages)
Logic Board Firmware Upgrade Programmer ICD-U64 Procedure
Brand:
Emerson
| Category:
Controller
| Size: 8.86 MB
Table of Contents
Table of Contents
3
Section 1: Firmware Upgrade
5
Tools
5
ICD-U64 Programmer Preparation
7
Firmware Update
8
Firmware Upload
8
Actuator Settings Checklist
20
Advertisement
Advertisement
Related Products
Emerson SW93
Emerson Fisher S201
Emerson Fisher S201K
Emerson SI-DeviceNet
Emerson Site Supervisor
Emerson Fisher SR5
Emerson TESCOM SG1 Series
Emerson TESCOM SG2 Series
Emerson TESCOM SG3 Series
Emerson S402Y
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL