Oil Injection Fittings Flow Test

Make sure the oil injection fittings of the cylinder
and crankcase assembly allow fluid to move.
Remove oil distribution hose from oil distribution
manifold.
Use a Syringe, P/N 346936, filled with isopropyl
alcohol to force fluid through hose and fitting.
1. Syringe

LOW OIL Sending Unit Test

Remove the oil from the oil tank.
Turn the key switch ON. The dash mounted
Engine Monitor system should show a LOW OIL
warning.
Once the warning has been confirmed, refill the oil
tank and start the outboard. The LOW OIL warn-
ing should stop after the oil pump cycles 3 times.