Timing Verification; Calibration Of Tps - Evinrude E-TEC E40DRLSCB Service Manual

Table of Contents

Advertisement

Repeat the entire adjustment process to make
sure pointer is aligned correctly.
Install spark plugs. Refer to Spark Plug Indexing
on p. 76.

Timing Verification

Use Evinrude Diagnostics software to synchronize
the mechanical timing of the outboard with the
electronic timing of the EMM.
Ignition Timing Screen
Check ignition timing after any of the following
procedures:
Powerhead replacement
Crankshaft replacement
Flywheel removal or replacement
CPS replacement
EMM replacement
EMM software replacement (reprogramming)
IMPORTANT:
Make sure the timing pointer is
set and the outboard reaches operating tempera-
ture before making any timing adjustments.
TPS Calibration
Use Evinrude Diagnostics software to tell the
EMM what throttle position sensor voltage is when
the throttle plates begin to open.
Remove the air silencer.
On the Settings screen of the diagnostics soft-
ware, click the "Set TPS Calibration" button.
1
1. TPS Calibration button
While holding the throttle plates closed, advance
the throttle linkage until it stops. The "Measured
006547
TPS Calibration" field on the screen will increase.
Click the "Working" button in the software to cali-
brate the TPS.
Install the air silencer.
Set TPS Calibration after replacing or adjusting
any throttle body or throttle linkage parts.
ELECTRICAL AND IGNITION
TIMING ADJUSTMENTS
006548
7
143