Evinrude E-TEC E40DRLSCB Service Manual page 13

Table of Contents

Advertisement

Minimum Battery
Requirements
Alternator
Tachometer Setting
Engine Fuse
Thermostat
Maximum Temperature
Water pressure
Type
Firing Order
Ignition Timing
RPM Limit in Gear
RPM Limit in Neutral
Crankshaft Position Sensor Air
Gap
Spark Plug
Gear Ratio
Lubricant
Capacity
Shift Rod Height
Shift Cable Stroke
Lubrication
Fluid Capacity
Trim Range
Tilt Range
40 – 65 HP E-TEC Models
640 CCA (800 MCA) or 800 CCA (1000 MCA) below 32° F (0° C)
Refer to Emission Control Information Label
Champion
HPF Pro in high performance or commercial applications
20 in. (L) Models: 21.38 (543 mm) ± one-half turn
1.125 to 1.330 in. (28.6 to 33.8 mm) measured between NEUTRAL and FORWARD
Evinrude/Johnson Biodegradable TNT Fluid
SERVICE SPECIFICATIONS
25-Amp fully regulated
6 pulse (12 pole)
P/N 967545 – 10 A
143°F (62°C)
212°F (100°C)
11 psi minimum @ 5000 RPM
Capacitor Discharge
1-2
EMM Controlled
6250
1800
Fixed
QC10WEP @ 0.028 ± .003 in. (0.71 mm)
12:32 (.375)
HPF XR Gearcase Lube
22 fl. oz. (650 ml)
15.2 fl. oz. (450 ml)
0° to 15°
16° to 65°
INTRODUCTION
11

Advertisement

Table of Contents
loading

Table of Contents