Oil Control Settings; Tiller/Remote Programming; Set Oil Type; Powerhead Break-In - Evinrude E-TEC E40DRLSCB Service Manual

Table of Contents

Advertisement

ENGINE MANAGEMENT MODULE (EMM)
DIAGNOSTIC SOFTWARE FUNCTIONS

Oil Control Settings

Set Oil Type

The TC-W3 oil type setting is the standard setting
for all outboards. Set TC-W3 for:
Operation with all TC-W3 outboard oils includ-
ing XD30, XD50, or XD100.
Applications requiring maximum lubrication.
Extreme applications (racing or harsh condi-
tions)
The XD100 setting provides an option to run the
outboard at a reduced oil injection rate. This set-
ting REQUIRES the use of Evinrude XD100 out-
board lubricant and is not recommended for all
applications.
Use the XD100 setting for:
Conventional use (runabouts, cruisers)
Moderate applications
1. Oil control setting
CAUTION
Running an Evinrude E-TEC outboard on
other grades of oil while set to the XD100
oil ratio will result in increased engine
wear and shortened outboard life.
98

Powerhead Break-In

Use the diagnostics software to start break-in oil-
ing after a powerhead rebuild. The break-in oiling
program runs for two hours of outboard operation,
above 2000 RPM.
1
1. Break-in oil setting

Tiller/Remote Programming

This feature controls the start in gear protection
function of the neutral switch. Tiller operated mod-
1
els, including remote models with an installed tiller
conversion kit, MUST be set to TILLER.
006540
1. Starter mode setting
006540
1
006540

Advertisement