55 V Alternator Circuit Test - Evinrude E-TEC E40DRLSCB Service Manual

Table of Contents

Advertisement

ELECTRICAL AND IGNITION
CHARGING SYSTEM TESTS
Start and run the outboard at approximately 5000
RPM. Use the variable load tester to draw the bat-
tery down at a rate equivalent to the stator's full
output.
The ammeter should indicate nearly full output,
Approximately 25 A @ 5000 RPM.
Decrease the battery load toward 0 A.
Ammeter should show a reduced output. As the
current draw decreases, the battery voltage
should stabilize at approximately 14.5 V.
If results vary, check stator BEFORE replacing
the EMM. Refer to STATOR TESTS on p. 126.
55 V Alternator Circuit
Check battery ground cable for continuity.
With the key switch ON, check battery voltage at
battery (12 V), then check voltage on white/red
wires at J2 connector of EMM. Use Electrical Test
Probe Kit, P/N 342677 and a multimeter set to
read 55 VDC. Voltage at EMM connector should
be 0.5 to 1 V less than battery.
128
1. J2 connector
With outboard running at 1000 RPM, voltage on
white/red wires should increase to 55 V.
Voltage readings at a specific speed (RPM)
should be steady.
If there is any other reading, refer to STATOR
TESTS on p. 126. Inspect the stator wiring and
connections. Inspect the capacitor wiring, connec-
tions, and capacitor. Repair the wiring or replace a
faulty capacitor, stator, or EMM.
1
002291