Removing and replacing a power supply blank

CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
To remove the component:
Figure 30: Removing the blank
To replace the component, reverse the removal procedure.
Removing and replacing a hot-swap power supply
The server supports 1+1 redundant power supply for high line (1200W/200~240VAC) and low line (800W/
100~120VAC) in the data center and office-friendly server versions.
Table 44: Power redundancy configurations
Line voltage
High Line
(200-240)
High Line
(200-240)
Low Line (100-120) 1
Low Line (100-120) 2
Low Line (100-120) 2
1
A maximum of 8 DIMMs are supported in a configuration with low line AC voltage and 2 processors.
146
Removing and replacing a power supply blank
Power supply
Processor count
count
1
1 or 2
2
1 or 2
1 or 2
1
2
DIMM count
Redundancy
2 to 24
No
2 to 24
Yes
2 to 12
No
2 to 12
Yes
1
2 to 8
Yes