Installation Troubleshooting - HPE Integrity rx2800 i2 series User's & Service Manual

Table of Contents

Advertisement

NOTE:
Your display might not exactly match the display shown.
Log Entry 1: 01 Aug 2012 17:20:38
Alert Level 5: Critical
Keyword: INSUFFICIENT_SYSTEM_MEMORY
This HW configuration does not have enough memory for the OS to boot.
Logged by: integrated Lights Out
Data: Data field unused
A080274200E10001 0000000000000000
Log Entry 11: 02 Aug 2012 11:28:38
Alert Level 7: Fatal
Keyword: MEM_NO_MEM_FOUND
No memory found
Logged by: System Firmware
Data: Location - Blade (Blade Board)
E48000D109E10010 FFFFFFFFFFFFFF94
14. If either of the above IPMI alerts appear in the SEL, verify that the memory expansion board and
DIMMs are installed properly and if necessary, replace the memory expansion board and DIMMs.
15. If any of the previous Level 5 or 7 IPMI alerts appear in the SEL after the processor, memory
expansion board and DIMMs have been replaced, then replace the system board.
16. If the processor, memory expansion board, and DIMMs are all installed and functioning correctly, the
system boots to UEFI. The following messages appear in the SEL.
NOTE:
Your display might not exactly match the display shown.
Log Entry 11: 03 Aug 2012 11:04:58
Alert Level 2: Informational
Keyword: EFI_START
CPU starting to boot EFI
Logged by: System Firmware
Data: Major change in system state - State Change
5480020709E1000F 000000000011000C
Log Entry 12: 03 Aug 2012 11:05:20
Alert Level 2: Informational
Keyword: EFI_LAUNCH_BOOT_MANAGER
Launching EFI boot manager
Logged by: System Firmware
Data: Major change in system state - EFI
5480020B09E10011 0000000000000006
17. If these events do not appear and the system does not boot, then seek assistance.

Installation troubleshooting

Installation troubleshooting methodology
A server is tested before shipping. Failures encountered during installation can be due to damage that
occurred in transit. Re-seating connectors can resolve issues that result from rough handling. If you are
installing components or assemblies, you might encounter compatibility issues or incorrect installations. If
110
Installation troubleshooting
located in
socket 0,cpu 2,thread 0
located in
socket 0,cpu 2,thread 0
located in
socket 0,cpu 2,thread 0