HPE Integrity rx2800 i2 series User's & Service Manual page 98

Table of Contents

Advertisement

Table 22: SAS disk drive LEDs: RAID mode
Drive activity LED status Drive status LED
On, off, or flashing
On, off, or flashing
On
On
Flashing regularly (1 Hz)
Flashing regularly (1 Hz)
Flashing irregularly
Flashing irregularly
Off
98
Troubleshooting
Indication
status
Alternating amber
The drive has failed, or a predictive failure alert has
and blue
been received for this drive; it also has been
selected by a management application.
Blue
The drive is operating normally, and it has been
selected by a management application.
Regularly flashing
A predictive failure alert has been received for this
amber (1 Hz)
drive.
Off
The drive is online, but it is not active currently.
Regularly flashing
amber (1 Hz)
The drive is part of an array that is undergoing
capacity expansion or stripe migration, but a
predictive failure alert has been received for this
drive. To minimize the risk of data loss, do not
replace the drive until the expansion or migration is
complete.
Off
The drive is rebuilding, erasing, or it is part of an
array that is undergoing capacity expansion or stripe
migration.
Regularly flashing
The drive is active, but a predictive failure alert has
amber (1 Hz)
been received for this drive. Replace the drive as
soon as possible.
Off
The drive is active, and it is operating normally.
Amber
A critical fault condition has been identified for this
drive, and the controller has placed it offline.
Replace the drive as soon as possible.
IMPORTANT:
Replace the drive as soon as possible.
CAUTION:
Do not remove the drive. Removing a drive
might terminate the current operation and
cause data loss.
CAUTION:
Do not remove the drive. Removing a drive
might terminate the current operation and
cause data loss.
Table Continued

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ah395-9013j

Table of Contents