Figure 13: Attaching the feet

Connecting server cables

AC input power
The server can receive AC input from two different AC power sources. The power receptacles are located
at the rear of the server.
A maximum of two power supplies can be installed in the server. Installing two power supplies in the
server provides 1+1 redundancy, meaning that if one power supply fails, there is still enough power
supplied to the server to operate. You must promptly replace the failed power supply to restore 1+1
functionality.
All high-line (220 V) configurations are capable of 1+1 redundancy. Low-line (110 V) configurations can
maintain 1+1 redundancy as long as the total power consumed does not exceed 800 W.
A minimum of one power supply is required to power the server. If only one power supply is installed in
the server, there is no 1+1 capability.
Power states
The server has the following power states:
Standby power
Full power
Off
Connecting server cables
33