4 Parameter Copy Mode

4.2.4 Parameter Block List Display (LIST)

4.2.4

Parameter Block List Display (LIST)

The statuses of one of seven parameter blocks in the storage area of digital operator
are displayed in a list, and unnecessary parameter blocks can be deleted.
(1)
Operating Procedure
Step
Display after Operation
B B
1 : S E R V O → O P
1
2 : O P → S E R V O
3 : V E R I F Y
4 : L I S T
B B
0 0 : S G D V − R 7 0
2
0 1 : ∗ ∗ ∗ ∗
0 2 : ∗ ∗ ∗ ∗
0 3 : ∗ ∗ ∗ ∗
B B
0 0 : S G D V − R 7 0
3
0 1 : ∗ ∗ ∗ ∗
0 2 : ∗ ∗ ∗ ∗
0 3 : ∗ ∗ ∗ ∗
B B
0 0 : S G D V − R 7 0
4
F I L E D E L E T E
S t a r t
R e t u r n : [ M O D E ]
B B
0 0 : S G D V − R 7 0
D e l e t i n g
5
P a r a m e t e r s . .
4-12
− C O P Y −
− L I S T −
− L I S T −
− L I S T −
: [ W R I T E ]
− L I S T −
Keys
Open the parameter copy mode menu
display, and select "LIST" using the
or
The blinking menu is one that is being
selected.
Press the
The display changes to the parameter
block selection display.
Press the
parameter block (00 to 06) of the digital
operator that is to be deleted.
Press the
The display is switched to the deletion
execution display.
Press the
the parameter block.
If power is supplied to the motor and
RUN is displayed, "Not Available" will
be displayed when the
pressed. In this case, writing into SER-
VOPACK will be disabled.
Operation
Key.
Key.
or
Key to select a
Key.
Key to start deleting
Key is