YASKAWA JUSP-OP05A-1-E User Manual page 41

Ac servo drives
Hide thumbs Also See for JUSP-OP05A-1-E:
Table of Contents

Advertisement

(1)
Preparation
There are no tasks that must be performed before displaying the alarm history.
(2)
Operating Procedure
Use the following procedure.
Step
Display after Operation
1
2
A . D 0 0
1 : 7 2 0
0 0 0 0 0 0 3 2 6 5 1
2 : 5 1 1
0 0 0 0 0 0 0 9 0 4 3
3 : − − −
4 : − − −
3
Alarm history no.
4
Note: 1.
If the same alarm occurs after more than one hour, the alarm will be saved. If it
occurs in less than one hour, it will not be saved.
2. The display " .---" means no alarm occurs.
3. Delete the alarm history using the parameter Fn006. The alarm history is not cleared
on alarm reset or when the SERVOPACK main circuit power is turned OFF.
− A L A R M −
Time stamp
Alarm no.
0: Latest
9: Oldest
Keys
Press the
menu for the utility function mode.
Use the
through the list and select Fn000.
Press the
to the Fn000 execution display.
Press the
through the alarm history. The alarm his-
tory can be viewed.
Press the
The display returns to the main menu of the
utility function mode.
3.2 Operations
Operation
Key to view the main
or
Key to move
Key. The display changes
or
Key to scroll
Key.
9 3
3-7

Advertisement

Table of Contents