3 Utility Function Mode
3.2.29 One-parameter Tuning (Fn203)
Step
Display after Operation
7
8
9
10
3-74
Keys
Press the
LEVEL setting screen.
If readjustment is required, select the digit
with the
LEVEL with the
Check the response.
If readjustment is not required, go to step 9.
Note: The higher the level, the greater the
responsiveness will be. If the value
is too large, however, vibration will
occur.
• If vibration occurs, press the
The SERVOPACK will automatically
detect the vibration frequencies and
make notch filter or an anti-resonance
control settings. When the notch filter is
set, "NF1" or "NF2" will be displayed
on the bottom row. When the anti-reso-
nance control is set, "ARES" will be dis-
played in the lower right corner.
• If the vibration is great, the vibration fre-
quency will be detected automatically
even if the
a notch filter or an anti-resonance con-
trol will be set.
Press the
screen will be displayed after LEVEL
adjustment.
• Press the
adjusted values. After the data is saved,
"DONE" will flash for approximately
two seconds and then "RUN" will be
displayed.
• To return to the previous value, press the
Key.
• Press the
without saving the values.
(cont'd)
Operation
Key again to display the
or
Key or change the
or
Key.
Key.
Key is not pressed and
Key. A confirmation
Key to save the
Key to readjust the level