∗2.
The output signal monitor Un006 is displayed as follows. The upper portion indicates the
OFF status, the lower portion indicates the ON status. The undefined digits are displayed
in the lower portion (ON status).
U n 0 0 6 =
8 7 6 5 4 3 2 1 digit
Display
LED
Output Terminal Name
Number
CN1-31, C-32
1
(cannot be allocated)
2
CN1-25, C-26 (can be allocated)
3
CN1-27, C-28 (can be allocated)
4
CN1-29, C-30 (can be allocated)
CN1-37
5
(cannot be allocated)
CN1-38
6
(cannot be allocated)
CN1-39
7
(cannot be allocated)
8
∗3.
The output signal monitor Un015 is displayed as follows. The upper portion indicates the
ON status, the lower portion indicates the OFF status. The undefined digits are displayed
in the lower portion (OFF status).
U n 0 1 5 =
8 7 6 5 4 3 2 1 digit
Display
LED
Output Terminal Name
Number
1
CN8-3, C-4 (cannot be allocated) /HWBB1 (Hard Wire Baseblock 1) input
2
CN8-5, C-6 (cannot be allocated) /HWBB2 (Hard Wire Baseblock 2) input
3
4
5
6
7
8
2.2 Monitor Mode
Signal Name (Factory Setting)
ALM (Servo alarm) output
/COIN (Positioning completion) output
or /V-CMP (Speed coincidence) output
/TGON (Detection during servomotor
rotation) output
/S-RDY (Servo ready) output
AL01 (Alarm code) output
AL02 (Alarm code) output
AL03 (Alarm code) output
Signal Name