YASKAWA JUSP-OP05A-1-E User Manual page 130

Ac servo drives
Hide thumbs Also See for JUSP-OP05A-1-E:
Table of Contents

Advertisement

3 Utility Function Mode
3.2.33 Online Vibration Monitor (Fn207)
Step
Display after Operation
3
4
5
6
3-96
Keys
Press the
ond to start vibration detection. The
Key must be pressed until "Measure"
flashes on the display. After this message
appears, the
be pressed and the detection continues
automatically.
When the vibration detection has com-
pleted, "Measure" stops flashing and the
detection processing ends automatically.
When the detection processing has com-
pleted normally, the vibrations with three
largest peak values in vibration frequency
are displayed for F1, F2, and F3.
Notes:
• Press the
vibration monitor function. The display
returns to the main menu of the utility
function mode.
• A detected frequency can be displayed.
For a vibration with undetectable peak
frequency, "----" is displayed. If no fre-
quency was detected, "----" is displayed
for F1, F2, and F3.
• If the frequency could not be success-
fully detected, "NO MONITOR" is dis-
played.
After the detection has normally com-
pleted, press the
frequency (time constant) of notch filter or
torque reference filter for F1 is set auto-
matically. At the same time, the parameter
Pn409 is updated for a notch filter, or the
parameter Pn401 is updated for a torque
reference filter.
After the setting is successfully completed,
"DONE" flashes.
Press the
The display returns to the main menu of the
utility function mode.
(cont'd)
Operation
Key for at least one sec-
Key does not have to
Key to quit the online
Key. The optimum
Key.

Advertisement