Offset Adjustment Of Analog Monitor Output (Fn00C) - YASKAWA JUSP-OP05A-1-E User Manual

Ac servo drives
Hide thumbs Also See for JUSP-OP05A-1-E:
Table of Contents

Advertisement

3 Utility Function Mode

3.2.11 Offset Adjustment of Analog Monitor Output (Fn00C)

3.2.11 Offset Adjustment of Analog Monitor Output (Fn00C)

This function is used to manually adjust the offsets for the analog monitor outputs
(torque reference monitor output and motor speed monitor output). The offset values
are factory-set before shipping. Therefore, the user need not usually use this function.
Note: • The adjustment value will not be initialized when parameter settings are initialized
(1)
Preparation
The following condition must be met to adjust the offsets of the analog monitor out-
put.
• The write prohibited setting (Fn010) must not be set to write-protect parameters.
(2)
Operating Procedure
Use the following procedure.
Step
Display after Operation
1
2
3
4
3-28
using Fn005.
• Make offset adjustment with a measuring instrument connected, so that the analog
monitor output is zero.
Keys
Press the
menu for the utility function mode.
Use the
through the list and select Fn00C.
Press the
changes to the Fn00C execution dis-
play.
Press the
adjust the offset of CH1 (torque refer-
ence monitor).
Adjust the offset so that the measure-
ment instrument reading is as close to 0
V as possible.
After the offset adjustment of CH1 has
completed, adjust the offset of CH2
(motor speed monitor).
Press the
moves to CH2 side.
Operation
Key to view the main
or
Key to move
Key. The display
or
Key to
Key. The cursor

Advertisement