adVanCed feaTures (COnTInued)

station delay

This feature allows the user to insert a delay time between when one station
turns off and the next station turns on. This is very helpful on systems with
slow closing valves, or on pump systems that are operating near maximum
flow or have slow well recovery. Different time delays between stations can
be set according to each Program (from 1 second to 9 hours).
eXP: StatIon deLay for PrograM a 2 MInuteS
Turn the dial to the adVanCed feaTures position. Use the ▲ and ▼
buttons select Staion Delay and press the + button to enter the Station
Delay screen. While in the Station Delay screen press the + / – button
to increase or decrease the delay time between stations according to a
Program. Use the Prg button to change between Programs A, B, C, or D.

no Water Window

This feature provides the user the ability to disable automatic watering
during certain times of the day specific to a Program.
Turn the dial to the adVanCed feaTures position. Use the ▲ and
1.
▼ to select no Water Window and use the + button to enter.
With the ► cursor next to Start, use the + / – button to set the start of
2.
the No Water Window.
Use the ▼ button to select the End time.
3.
With the ► cursor next to End, use the + or – button to set the end of
4.
the No Water Window.
for example: if the No Water Window Start is set at 8:00 AM and the No Water
Window End is set at 5:00 PM, the controller will not irrigate during the period
of the day between 8:00 AM to 5:00 PM. Press the PRG button to change
Programs to set a different No Water Window period for each program.
If an automatic Program or Manual Program overlaps and runs into a No
Water Window period, the controller will Suspend the watering of the
Program being run.
24
The program will continue to count down the run times associated with the
program. If the No Water Window expires and the program is still counting
down a run time, the controller will begin watering at that point in time.
Once the program finishes and the display returns to the current date and
time screen, a fault message will be displayed indicating irrigation has
violated the No Water Window and which program was in violation.
This message is displayed to make you aware that irrigation has been missed
or Suspended and supplemental watering may be necessary to make up the
missed irrigation that has occurred during the No Water Window. A manual
single station that is activated remotely or at the controller will override the
No Water Window and be allowed to water.

firmware Info

This feature shows the revision of firmware loaded into the I-Core controller.
easy retrieve
Memory
The Easy Retrieve feature allows you to save your preferred watering
program and settings into memory for retrieval at a later time. This
feature allows for a quick way of resetting the controller to the original
programmed watering schedule if for some reason the programming was
tampered with.