InsTallInG sTaTIon modules.....................................................
ACC expands in 6-station increments with intelligent output modules, requiring no tools to install and only a screwdriver
for station wiring connections. The base configuration is 12 stations (two 6-station modules installed) with a maximum
station capacity in a metal wall cabinet of 42 stations (7 total output modules x 6 stations each).
ACC can be expanded at any time with either of the following types of modules:
1. ACM600, 6-station output module with surge suppression and diagnostic LEDs
2. AGM600, 6-station output module with heavy-duty surge suppression and diagnostic LEDs
These two types of modules may be mixed within the same installation if desired.
OutPut MODuleS (ACM600, AGM600)
A. Station Output Screw Terminals – Connect no more
than two solenoids each.
B. Station Status LEDs – Green for station activity, Red
for fault or short
C. Locking lugs – For module lock
D. Gold plated electrical contacts – Lower rear of
module
E. Additional surge components, AGM versions –
Visible through module
ACM600
6-station output
module
11
Station Modules
D
C
b
A
e
AGM600
6-station output module with
heavy duty surge protection
1. To install expansion modules, turn the dial to the
"Run" position.
2. Open the inner facepack door, and locate the module
lock. Slide the module lock to the "Power Off"
position.
3. Flip up the upper deck cover. Slide the modules up,
into the next available position, viewed from left to
right. Do not skip slots by leaving them empty.
4. Install a module by aligning it firmly in the lower
portion of the next available slot and sliding straight
up until it clicks into place. Once module is in place,
slide power bar to the "Power On" position. The
first two lights of the bottom and top row of each
module installed will light up red for 1 second,
indicating proper contact and the new module has
been recognized. The red lights will then turn off, in
sequence, from left to right across the modules that
are installed.
5. The silver contact on the back of the controller
cabinet must engage a mating slot in the back of the
expansion module. Do not "tip" or force the module
into place. Slide straight up, from the bottom of
the slot.
6. While at the Run dial position, press the Information
button. The current station size will be shown, and
should include any new modules you have added.
24
ET
FLOW SEN4
SEN3 SEN2 SEN1
VAC
P/M1 P/M2
4
5
6
1
2
3
ET
FLOW SEN4
SEN3 SEN2 SEN1
COM
US PATIENT NO 6,842,667 B2
10
11
12
16
17
18
22
23
24
28
29
30
34
35
36
40
41
42
7
8
9
13
14
15
19
20
21
25
26
27
31
32
33
37
38
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents