• Extended Feature: Change the master valve from the
default of normally closed (N.C.) to normally on (N.O.)
Change the location of the P/MV between Controller
(wired directly into the Master Module) and ADM
(P/MV is connected to a decoder on the two-wire path)
Set Pump and Master Valve Operation
1. Turn the dial to the SET PUMP OPERATION position
2. Press the right and left arrow buttons to move
between P/MV 1 and P/MV 2
3. Press the up and down arrow buttons to change the
station number
4. Press the + or – button to enable or disable the
specific Pump or Master Valve for the given station
Changing from Normally Closed to Normally On and
Location of P/MV
Programming this feature is explained in the Extended
Features section.
SettInG StAtIOn CyCle AnD SOAK DurAtIOnS
Each Station's Cycle and Soak settings are programmed at
this position. Cycle and Soak allows the user to break up
the total run time of a station into more usable watering
durations (cycles), and a minimum soak time between the
watering cycles. This feature is great to use on slopes and
tight soils because it puts the water down more slowly,
helping to prevent run off.
Set Station Cycle and Soak Durations
1. Turn the dial to the SET CYCLE AND SOAK position
2. Press the up or down arrow keys to change stations
3. Press the right and left arrow buttons to move
between hours and minutes and cycle and soak
24
4. Press the + or – button to change the Cycle cursor
value. The default cursor value is N/A. Cycles can be
set from 1 minute to 6 hours.
5. Press the right arrow button to move from Cycle to
Soak, once a value has been entered into the Cycle
field.
6. Press the + or – button to change the Soak cursor
value. The default cursor value is N/A. Soaks can be
set from 1 minute to 9 hours.
7. Press the down arrow to move to the next station.
8. The Copy and Paste functions are useful for large
numbers of stations with similar Cycle and Soak
requirements. To use, set a station's Cycle and Soak
information, then press the Copy button.
9. Use the up or down arrows to advance to the next
station, and press Paste. Both the Cycle and Soak
value will be pasted into the fields.
You can continue to advance through the stations with the
up or down arrows, and press Paste to continue pasting
the same Cycle and Soak values into subsequent stations.
CyCle AnD SOAK SuMMAry
In the Set Cycle and Soak dial position, press the
Information button to view a summary of Cycle and Soak
with any selected station's run time. It will display the total
run time of that station per Start Time in the program, not
including the soak time. It will also display the station's
programmed cycle time and soak time, and the number
of cycles that station will incur due to the programmed
runtime and cycle time. If the station's run time is less
than one complete programmed cycle time, the number of
cycles displayed will be shown as 0+. To view Cycle and
Soak summaries for stations in other programs, simply
release the Information button and while in the Cycle
and Soak screen, hit the Program button. Hold down
the Information button again and the display will now
show that station's Cycle and Soak summary for the new
program.