Hunter X-Core Owners Manual And Programming Instructions page 135

Residential irrigation controller
Table of Contents

Advertisement

1.
Hold down the Information button, and turn the dial
back to the Set Program Overlap Options position.
2. Release the Information button to view the SSG
Setup screen.
3. The first SSG will be displayed and highlighted.
Change to a different SSG by pressing + or – to move
through all SSGs.
4. When the SSG to be edited is selected, use the down
arrow to move to the stations area of the display.
5. To replace a station in an SSG (with a different
station): Highlight the station to be replaced. Press
the + or – buttons to change the line to the new
station number.
6. To delete a station in an SSG (without replacement):
Highlight the station to be replaced, and use the + or
– buttons until the dashed line appears. This choice
appears between the highest numbered station,
and the lowest station remaining which has not
been assigned to an SSG. Leave the dashed line and
move to a different field in the display with the arrow
buttons.
7. To add a station to an SSG: Use the down arrow to
move to the next blank dashed line.
8. Use the + or – to select the station to be added.
Once all 4 lines are full (contain station numbers or
names), the SSG is full and no more can be added.
ADDInG An SSG
Enter the SSG Setup mode (Information + Set Program
Overlap Options).
The first SSG will be highlighted.
Use the + button to advance through all existing SSGs,
until the next unused SSG appears (having all dashed lines
with no station selections), and select stations as desired.
49
Once the controller is in ACC Setup mode, all 20 SSGs are
available, whether they are used or not.
DELETING AN SSG
Technically SSGs are never deleted, as there are always
20 available.Instead, simply select the unwanted SSG,
and delete the stations contained in it until no stations are
listed under the SSG name.
SSG FLOW DATA
SSGs use the combined learned flow data for all their
member stations. They do not have a flow assigned
directly to them. If the stations in an SSG are edited
(added or deleted), the flow for the whole SSG will change
by the amount of that station.
SSG ruleS
A station which is included in an SSG may still be started
separately at the Manual Operation function or from the
ICR remote control.
A station which is included in an SSG is not available for
individual placement in automatic Programs, while the
controller is in SSG/SmartStack mode.
In the Set Station Run Times position, individual stations
which are SSG members will be shown, but their run times
will show as *:**:** and cannot be changed. The display
will show the number of the SSG to which they belong, and
the run time for the SSG should be changed instead.
SSGs are shown at the end of the station list when setting
run times, and most other functions. For example, in a 12
station controller, the stations would be displayed as 1, 2,
3...12 followed by SSG 01, SSG 02, etc.
Beginning from station 01, use the – button to see the
SSGs quickly (like going backward from the beginning of
the list to the end of the list).