Hunter X-Core Owners Manual And Programming Instructions page 89

Residential irrigation controller
Table of Contents

Advertisement

WIrInG ComparTmenT InTerIor ................................................
1. Inner Door – Opens to main wiring compartment
2. AC Wiring compartment – For connection of 120/230V
AC power with 1 x 0.75" (19 mm) conduit opening
3. fuse – 2 Amp (fast) 250V, 6 x 20 mm
4. Conduit Openings, low Voltage – 2" x 2½" (64 mm),
2" x ¾" (19 mm)
5. Wire tie holders for Valve Wires – Valve wiring area
6. Station Output terminals (Valve Wires) – screw
terminals on 6-station output modules
7. upper Deck Panel with led Status Indicators –
Numbered station lights, green for active, red for faults
8. Sliding lock for Output Modules – Permits addition
or removal of output modules, locks wired modules
in place
~
Explanation of Symbols
AC
Consult Documentation
3
1
10
2
3
11
9. Master Module – Includes sensor, Pump/Master
Valve, and other accessory connections
10. SmartPort
– Integrated connector for ICR/SRR
®
receiver (on side of cabinet)
11. earth Ground lug – For connection of earth ground
copper wire (for surge protection only). Do not
connect valve commons – see Master Module for
Common wiring of solenoids and valves.
Hazardous Voltage Present
Double Insulated
9
7
8
4
5
6

Hide quick links: